Williams 5557331 - 55,000 BTU Propane Gas Forsaire Direct-Vent Counterflow Intermittent Ignition Furnace

This is a High Altitude Model for 6,001 ft to 8,000 ft Elevation - See Other Wall Heater Models for0 ft to 8,000 ft Elevations

Efficiently designed comfort heating! This models powerful Counterflow blower system receives air at ceiling level, warms it and quietly delivers it at floor level to give an equalized floor-to-ceiling temperature! Installs easily and inexpensively.

The forced-air circulation comfort heating system uses only outside air for combustion, as the burners are completely sealed within the combustion chamber. Combustion products are discharged outdoors through the wall vent. This eliminates the expense of a vent. All vent caps include a built-in GÇ£Bird-Guard.GÇ¥ All vent material is included. Ideal for garages.

Product Design Features:

Freestanding or recessed, Forsaire furnaces are ideal for homes, apartments, offices, schools, cabins and many other applications. Counterflow blower system circulates ceiling-to-floor warm air. GÇ£MatchlessGÇ¥ pilot igniter. Multi-room heating with optional outlet accessories to heat up to three rooms. Equipped with a four-foot service cord. Natural or propane models (conversion kits available). Automatic temperature and safety controls. Resettable vent-limit safety switch (top-vent models). Thermostat included.

Product Specifications Overview:

Btu/hr Input Rating: 55,000 Btu/hr Output Rating: 42,500 Efficiency Percentages: Thermal - 77.0 AFUE - 76.5 Dimensions: 87'H x 11-3/4'D x 14-1/8'W Blower Speeds: 2 CFM @ 115V: 440 Amps: 3.0 Pilot Type: Intermittent Ignition Shipping Weight: 140 lbs Gas Connection Size:1/2' Gas Type: Propane Gas Equipped with a 24V control valve and wall thermostat. Clearances: 4' to an intersecting wall 4' from the top of the furnace to ceiling or overhang 0' to finished floor 59' from the finished floor to the centerline of the vent cap for Model Series 40073 and 40077 68-1/2' from the finished floor to the centerline of the vent cap for Model Series 55073 and 62577

Wide Selection of Accessories Available (Click for Link):

Gas Conversion Kits: Natural Gas to Propane Gas (WIL 7730) Propane Gas to Natural Gas (WIL 7731) Rear and Side Outlets - Allows heat to be ducted into a rear or side room: Side-Outlet Register with 10' boot for top-vent and direct-vent models (WIL 6701) Side-outlet Grille for top-vent and direct-vent models (WIL 6702) Front Diffusing Grilles - A snap-on grille used to divert heat to the right, left or both direction: Two-Way Directional Diffuser Grille (WIL 6703) One-Way Directional Diffuser Grille (WIL 6704) Venting Accessories - Simplify the installation process with these accessories: Vent Shield Deflector, Insulated, galvanized metal sheet for Direct-Vent models (WIL 4318) Thin Wall Collar, for wall thicknesses 1' to 5,' used with Direct-Vent models (WIL 9307) Vent Cap Guard, protects pedestrian traffic from heat of the vent cap (WIL 9308) Direct-Vent Tube Extension, 12' length (WIL 9806) Finishing Items - Clean up the installation of your furnace with these finishing items:Metal Finishing Strips painted the same color as the furnace (WIL 4701) Miscellaneous Accessories - Other items you may need to install the furnace:Hardwired Adapter, used for wiring from a junction box rather than using the power service cord (WIL 9940)

Shipping Note:

Are the shipping rates for this equipment coming through a little high?Please remember that this is a large piece of equipment. Because of its larger size (dimensions and weight), higher freight charges may apply and this item will have to ship via truck line on a pallet. If you have any questions about shipping, or would like to get a shipping quote for your order, please don't hesitate to contact one of our sales reps at 866-519-2461; we'd be happy to help you with your purchase!

Important Notes When Buying a New Williams Furnace:

Read the owner's manual before using/installing. Photographs see on this page are representative only. Check local codes and ordinances for permitted uses. Consult installation manual for clearances prior to installation. We reserve to right to amend product specifications without notice. Installation and servicing is required by a qualified service person. Venting must comply with the installation manual. New York approval MEA197-82E Vol 111 on direct-vent models only. Massachusetts approval G3-0305-171. Please read the warranty for any limitations for disclaimers. Combustion chamber carries a ten-year limited warranty; all other parts carry a one-year limited warranty.

Download Our Manuals

Currently no manuals available for this product. Please check product description or call our sales support team if you have any further queries.

Series Forsaire Counterflow Series
Input BTU 55,000
Power Type Propane (LP)
AFUE Efficiency % 76.5
Operating Altitude 6001 ft to 8000 ft
Thermal Efficiency % 77
Vent Type Direct Vent
Pilot Type Intermittent
Equipment Description Wall Heaters